Search Skip navigation

Service Manuals Please log in or register to download service manuals.
Where to buy

Find your nearest authorised COE retailer

Search for retailer

X-Net Contact Closure Card

CC16 group_shot  
X-Net CC-16 Contact Closure Card
X-Net Product Range

The X-Net CC-16 module may act as a companion card to any X-Net module to provide easy expansion of alarm signalling. It features 16 contact closure inputs and 16 relay outputs.

Increasingly, it is necessary to connect multiple external devices (such as PIR sensors and tamper alarms) to the video transmitters to be transmitted back to a central control room. Most X-Net modules have two contact closures but in case more contact closure channels are required, CC-16 module offers a cost effective way to expand the system. With a pair of CC-16 modules, it is possible to add up to 16 contact closures to any X-Net module.

Features & Benefits

  • Add up to 16 contact closure channels - Flexibility to add new devices to the CCTV network without having to replace existing modules

  • Receive alarms using SNMP - Using the X-Net NMS card, SNMP traps can be generated for alarms received by the CC-16 card. This can be very useful when external sensors (such as smoke detectors, infrared sensors etc.) are connected to CC-16

  • Possible to Daisy Chain multiple cards - In case more alarms are required, it is possible to Daisy Chain multiple CC-16 cards

  • Native Telecommand support - CC-16 can be directly connected to Telecommand to launch a sequence of actions in response to an alarm (such as pointing cameras to a certain position, starting recording on DVRs etc.)

Technical Specification

Contact Closure
Channels

16 (duplex)

Format

TTL/Grounding Input, FET Relay output

Response Time

<1ms

Maximum Relay rating

48V DC/AC, 100mA

Contact Resistance

25 Ω (Typical), 50 Ω (Max)

Connector

RJ45

Configuration: When the input is pulled low (i.e., shorted to ground), the corresponding output relay will also be on (i.e. closed).
Data Channel 1
Channels

1

Rate

19.2 kbps

Format

RS232/RS422/RS485 2W/4W

Connector

RJ45

Line Biasing

Switchable

Failsafe

Switchable

Jitter

<12%@max bit rate

Environmetal
Operating temperature

-40 °C to +74 °C

Storage temperature

-40 °C to +74 °C

Endurance

1000 hours

Humidity

5% to 95% (Non Condensing)

Mechanical
Dimensions

12HP x 4U x 167mm

Rack Slots

2

Power requirements
Supply Voltage

9 to 14V DC or 24V AC

Card Protection

Poly Fuse

Current Consumption

<500mA (typical @ 12V)

Edge Connector

Samtec Power-Mate (10 way) (IPBT-11-H1-T-D-RA-GP)

MTBF
CC-16

>100,000 hours

EMC
EN55022 Class B, EN61000-3-2 Class A, EN61000-3-3, EN61000-4-2 6kV(C), 8kV (A), EN61000-4-3 10V/m, EN50204 20V/m, EN61000-4-6 10V, EN61000-4-4 2kV
Top

Enquire about this product

Mandatory information*