Service Manuals
Please
log in or
register to download service manuals.
Case Studies
-
Airports
-
Military/Secured Site
-
Public Space
-
Rail
-
Roads & Tunnels
-
Sea Ports
X-Net Network Management Card
X-Net NMS is a Network Management module for remote diagnostics and alarm reporting of X-Net products via SNMP or web browser interface.
With increasing convergence of IT and CCTV technologies, modern CCTV networks have grown tremendously and have become very complex. With equipment spread over hundreds of kilometers, the diagnostics of the equipment out in the field can be a nightmare for a CCTV manager. But with the X-NET NMS card, a CCTV operator can monitor the health of all his X-Net modules without ever having to leave the control room.
Features & Benefits
Collects data from local and remote racks - Thus only one NMS card is required for a pair of racks.
Report alarms via serial, ethernet or contact closure interfaces - Can even trigger a SNMP trap in response to an external alarms connected to the contact closure channel, thus enabling remote monitoring of devices which otherwise don’t support SNMP.
Generate alarms on faults in X-Net optical modules/ codec - Can detect video loss, laser faults, Data Errors, Extended distance faults for optical modules, Temperature, Extended power supply status (temperature, fan status, voltage etc.)
Seamless integration into COE Telecommand – COE Telecommand can be used to trigger complex actions such as switching matrices, macros, salvos, tours etc. in response to alarms generated by NMS card.
Technical Specification
| Alarms & Monitoring |
| Data |
Data format, data status (low,
high, data), Data parity errors |
| Optical |
Slot address, Laser Status, Loss of
Signal, Rx Alarm |
| Advanced Optical |
Laser current, Laser Temperature,
Optical received power. These
alarms are available with special
lasers. Please contact COE sales
for more information |
| Codec |
Temperature, Slot Address,
Status, IP address, Resolution &
framerate, Bandwidth usage |
| General |
Board Temperature, Slot Address,
Video status |
| Power Supplies |
Temperature, slot address, status,
fan, voltage, current |
| NOTE: New status information may be added and old ones
removed via software updates at any time. If you need a
specific status, please contact COE Sales to confirm. |
| Data Channel 1 |
| Channels |
1 |
| Format |
RS232 |
| Rate |
0-128kbps |
| Connector |
RJ45 |
| Jitter |
<12%@max bit rate |
| Data Channel 2 (Telecommand/3rd party) |
| Channels |
1 |
| Format |
RS232/RS422/RS485 2W/4W |
| Line Biasing (RS485) |
Switchable |
| Failsafe |
Switchable |
| Connector |
RJ45 |
| Jitter |
<12%@max bit rate |
| Contact Closure |
| Channels |
4 (duplex) |
| Format |
TTL/Grounding Input, FET Relay
output |
| Response Time |
<1ms |
| Maximum Relay rating |
48V DC/AC, 100ma |
| Contact Resistance |
25Ω (Typical),50Ω (Max) |
| Connector |
RJ45 |
| Ethernet |
| Channels |
1 |
| Interface |
IEEE E802.3 10/100 BaseT |
| Network |
Auto Sensing, full/half duplex |
| Connector |
RJ45 |
| Environmetal |
| Operating temperature |
-40 °C to +74 °C |
| Storage temperature |
-40 °C to +74 °C |
| Mechanical |
| Dimensions |
6HP x 4U x 167mm |
| Rack Slots |
1 |
| Power requirements |
| Supply Voltage |
9 to 14V DC or 24V AC |
| Card Protection |
Poly Fuse |
| Current Consumption |
<500mA (typical @12V) |
| Edge Connector |
Samtec Power-Mate (10 way) (IPBT-11-H1-T-D-RA-GP) |
| MTBF |
| NMS |
>100,000 hours |
| EMC |
EN55022 Class B, EN61000-3-2 Class A, EN61000-3-3, EN61000-4-2 6kV(C), 8kV (A), EN61000-4-3 10V/m, EN50204 20V/m, EN61000-4-6 10V, EN61000-4-4 2kV, EN61000-4-5 2kV, EN61000-4-8 50Hz & dc 100A/m, EN61000-4-9 300A/m, EN61000-4-11, EN609501:2002 + A1:2003, EN608252:2000 |
Top