X-Net Network Management Card

X-Net NMS X-Net NMS group_shot  
X-Net NMS
X-Net NMS

X-Net NMS is a Network Management module for remote diagnostics and alarm reporting of X-Net products via SNMP or web browser interface.

With increasing convergence of IT and CCTV technologies, modern CCTV networks have grown tremendously and have become very complex. With equipment spread over hundreds of kilometers, the diagnostics of the equipment out in the field can be a nightmare for a CCTV manager. But with the X-NET NMS card, a CCTV operator can monitor the health of all his X-Net modules without ever having to leave the control room.

Features & Benefits

  • Collects data from local and remote racks - Thus only one NMS card is required for a pair of racks.

  • Report alarms via serial, ethernet or contact closure interfaces - Can even trigger a SNMP trap in response to an external alarms connected to the contact closure channel, thus enabling remote monitoring of devices which otherwise don’t support SNMP.

  • Generate alarms on faults in X-Net optical modules/ codec - Can detect video loss, laser faults, Data Errors, Extended distance faults for optical modules, Temperature, Extended power supply status (temperature, fan status, voltage etc.)

  • Seamless integration into COE Telecommand – COE Telecommand can be used to trigger complex actions such as switching matrices, macros, salvos, tours etc. in response to alarms generated by NMS card.

Technical Specification

Alarms & Monitoring
Data Data format, data status (low, high, data), Data parity errors
Optical Slot address, Laser Status, Loss of Signal, Rx Alarm
Advanced Optical Laser current, Laser Temperature, Optical received power. These alarms are available with special lasers. Please contact COE sales for more information
Codec Temperature, Slot Address, Status, IP address, Resolution & framerate, Bandwidth usage
General Board Temperature, Slot Address, Video status
Power Supplies Temperature, slot address, status, fan, voltage, current
NOTE: New status information may be added and old ones removed via software updates at any time. If you need a specific status, please contact COE Sales to confirm.
Data Channel 1
Channels 1
Format RS232
Rate 0-128kbps
Connector RJ45
Jitter <12%@max bit rate
Data Channel 2 (Telecommand/3rd party)
Channels 1
Format RS232/RS422/RS485 2W/4W
Line Biasing (RS485) Switchable
Failsafe Switchable
Connector RJ45
Jitter <12%@max bit rate
Contact Closure
Channels 4 (duplex)
Format TTL/Grounding Input, FET Relay output
Response Time <1ms
Maximum Relay rating 48V DC/AC, 100ma
Contact Resistance 25Ω (Typical),50Ω (Max)
Connector RJ45
Ethernet
Channels 1
Interface IEEE E802.3 10/100 BaseT
Network Auto Sensing, full/half duplex
Connector RJ45
Environmetal
Operating temperature -40 °C to +74 °C
Storage temperature -40 °C to +74 °C
Mechanical
Dimensions 6HP x 4U x 167mm
Rack Slots 1
Power requirements
Supply Voltage 9 to 14V DC or 24V AC
Card Protection Poly Fuse
Current Consumption <500mA (typical @12V)
Edge Connector Samtec Power-Mate (10 way) (IPBT-11-H1-T-D-RA-GP)
MTBF
NMS >100,000 hours
EMC

EN55022 Class B, EN61000-3-2 Class A, EN61000-3-3, EN61000-4-2 6kV(C), 8kV (A), EN61000-4-3 10V/m, EN50204 20V/m, EN61000-4-6 10V, EN61000-4-4 2kV, EN61000-4-5 2kV, EN61000-4-8 50Hz & dc 100A/m, EN61000-4-9 300A/m, EN61000-4-11, EN609501:2002 + A1:2003, EN608252:2000