X-Net 12 Channel Data Fibre Transmission Module
X-Net DataMux for total data management
X-Net DataMux for total data management
The X-Net DataMux enables transmission of up to 12 data channels over a single optical fibre. The DataMux Tx and Rx may be used as a stand alone data transfer system, or in addition to various X-Net products, including the X-Net OPT4 and OPT8 models to increase the number of data channels permitted whilst retaining video feed simultaneously.
The X-Net DataMux provides a cost effective platform for increasing the data channels in installations where additional data channels are required for devices such as traffic light control systems, access control systems, alarm consoles etc. X-Net Datamux provides the flexibility to add additional data channels as and when required, as a standalone device or as a port extender. Both modes provide up to 12 independently configurable data channels.
Features & Benefits
Standalone or use as data expander – Flexible configuration to suit site requirements.
Add up to 12 high speed data channels – Flexibility to add new devices and functionality to a CCTV network without having to replace existing modules.
Independently Configurable – To ensure comparability with all devices.
Comprehensive 5 Year Warranty – All x-net modules are covered by a comprehensive 5 year warranty and have MTBF in excess of 100,000 hours.
Technical Specification
| Data |
| Channels |
12 (duplex) |
| Rate |
DC to 64kbps |
| Format |
RS232/422/485 2W/4W |
| Connector |
RJ45 |
| Line Biasing |
Switchable |
| Failsafe |
Switchable |
| Optical |
| Budget (dB) |
>20dB* |
| Range (Multimode fibre) |
4Km |
| Range (Singlemode fibre) |
50Km |
| Connector |
LC |
| Bitrate |
155Mbps |
| * Higher optical budgets available on request |
| MTBF |
| Duration |
>100,000 hours |
| Environmetal |
| Operating temperature |
-40 °C to +74 °C |
| Storage temperature |
-40 °C to +85 °C |
| Endurance |
1000 hours |
| Humidity |
5% to 95% (Non Condensing) |
| Mechanical |
| Dimensions |
12HP x 4U x 167mm |
| Rack Slots |
2 |
| Power requirements |
| Supply Voltage |
9 to 14V DC or 24V AC |
| Card Protection |
Poly Fuse |
| Current Consumption |
50mA (typical @ 12V) |
| EMC |
| EN55022 Class B, EN61000-3-2 Class A, EN61000-3-3, EN61000-4-2 6kV(C), 8kV (A), EN61000-4-3 10V/m, EN50204 20V/m, EN61000-4-6 10V, EN61000-4-4 2kV, EN61000-4-5 2kV, EN61000-4-8 50Hz & dc 100A/m, EN61000-4-9 300A/m, EN61000-4-11, EN60950-1:2002 + A1:2003, EN60825-2:2000 |